Prodcuts

Online Hydrogen Chloride Monitoring System

Product Description

The Model TK-1300 Hydrogen Chloride (HCl) On-line Monitoring System adopts high-temperature extractive sampling combined with Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology and features non-contact measurement, which provides a reliable guarantee for real-time and accurate reflection of HCl concentration changes.

  • Model

    TK-1300

Technical Specifications

  1. Optical Path Length (Extractive Type): 760 mm
  2. Measuring Range: 0~20 (ppm or mg/m³) (range customizable)
  3. T90 Response Time: < 120 seconds
  4. Measurement Accuracy: ≤ ±2% F.S.
  5. Minimum Resolution: ≤ 0.01 ppm
  6. Protection Grade: IP65
  7. Explosion-proof Marking: Explosion-proof version customizable, Exd Ⅱ CT4
  8. Digital Output: RS485, 4-20mA

Technical Advantages

  1. Reliable design of long optical path heated gas cell with optical path length up to 1520 mm
  2. Ultra-low concentration measurement with resolution up to 0.1 ppm
  3. The spectral width of the semiconductor laser is less than 0.001 nm, avoiding cross-interference from dust and moisture
  4. Simple equipment maintenance and low operating cost

You Might Also Like

View all
Home
Products
About Us
Contacts

Please leave us a message

    * Name

    *Email

    Phone / WhatsAPP / WeChat

    * What I have to say.