Prodcuts

Ammonia Slip Online Monitoring Equipment

Product Description

The Model TK-1100 Ammonia Slip Online Monitoring System adopts high-temperature heat tracing extraction technology combined with TDLAS (Tunable Diode Laser Absorption Spectroscopy) technology. Composed of three parts: sampling and transmission unit, preprocessing and control unit, and analysis unit, the system is mainly applied to gas emission monitoring and process control in a wide range of industrial fields, such as coal-fired power plants, aluminum plants, steel plants, smelters, waste-to-energy power plants, cement plants, chemical plants and glass plants.

  • Model

    TK-1100

Technical Specifications

  1. Optical Path Length (Extractive Type): 760 mm
  2. Measuring Range: 0~20 (ppm or mg/m³) (range customizable)
  3. T90 Response Time: < 120 seconds
  4. Measurement Accuracy: ≤ ±2% F.S.
  5. Minimum Resolution: ≤ 0.01 ppm
  6. Protection Grade: IP65
  7. Explosion-proof Marking: Explosion-proof version customizable, Exd Ⅱ CT4
  8. Digital Output: RS485, 4-20mA

Technical Advantages

  1. Reliable design of long optical path heated gas cell with optical path length up to 1520 mm
  2. Ultra-low concentration measurement with resolution up to 0.1 ppm
  3. The spectral width of the semiconductor laser is less than 0.001 nm, avoiding cross-interference from dust and moisture
  4. Simple equipment maintenance and low operating cost